Thank you for taking interest in Tyco Electronics Corporation part number A711JB, which is listed with the NSN 2925-00-294-2978 and a product description of “Cutout Relay Engine Generator.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number A711JB, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Cutout Relay Engine Generator part with the NSN 2925-00-294-2978. For example, you can browse other Tyco Electronics Corporation components that were produced under CAGE Code 74063 or listings that belong to FSC 2925 Engine Electrical System Components Aircraft Prime Moving with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number A711JB and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
2925-00-294-2978 Item PartTypeName: CUTOUT RELAY,ENGINE GENERATOR | 2925 | 002942978 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A711JB | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABWP | FRAME | ANY ACCEPTABLE |
AFSS | DESIGN CURRENT RATING IN AMPS | 600.0 MAXIMUM |
AHZV | SUBMERSIBILITY | NONSUBMERSIBLE |
AKPV | MOUNTING FACILITY QUANTITY | 4 |
ALBH | RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
ARKQ | MOUNTING FACILITY SPACING | 3.000 IN. BY 4.000 IN. MTG C |
AWYX | MOUNTING FACILITY SIZE | 0.196 IN. DIA |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
AXHT | VOLTAGE SYSTEM FOR WHICH DESIGNED | 24.0 VOLTS NOMINAL |
AXHZ | CUT-IN VOLTAGE RATING | 17.0 VOLTS NOMINAL |
AXMN | CUTOUT VOLTAGE RATING | 14.0 VOLTS NOMINAL |
AXMR | CUTOUT CURRENT RATING | 235.0 AMPERES NOMINAL |