Thank you for taking interest in Siemens Energy And Automation Inc part number B360M, which is listed with the NSN 5925-01-599-2747 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number B360M, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-599-2747. For example, you can browse other Siemens Energy And Automation Inc components that were produced under CAGE Code 66842 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number B360M and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-599-2747 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015992747 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
B360M | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CXCY | Part Name Assigned By Controlling Agency | CIRCUIT BREAKER |
CPLM | Maximum Continuous Load Current Rating Per Pole | 60.0 AMPERES AC SINGLE LOCATION |
AKPX | Pole Quantity | 3 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRL | Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL-MAGNETIC SINGLE LOCATION |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADAT | Body Width | 3.0 INCHES NOMINAL |
CPRW | Actuator Function | TRIP-RESET |
FEAT | Special Features | SUFFIX M FOR MARINE 50 DEG C AMBIENT CALIBRATION; CMS DATA ID 1658, PCCN SE0361, PLISN A005 |
ADAQ | Body Length | 3.75 INCHES NOMINAL |
AGAV | End Item Identification | PANEL, DISTRIBUTION; SENTINEL CLASS FAST RESPONSE CUTTER B (FRC-B) |
ADAU | Body Height | 2.375 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.0 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote