Thank you for taking interest in Sensata Technologies Inc part number IELBXK1-1-63-4.0, which is listed with the NSN 5925-01-596-7538 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number IELBXK1-1-63-4.0, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-596-7538. For example, you can browse other Sensata Technologies Inc components that were produced under CAGE Code 81541 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number IELBXK1-1-63-4.0 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-596-7538 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015967538 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
IELBXK1-1-63-4.0 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 0.000 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 4.0 AMPERES AC SINGLE LOCATION |
FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES MAXIMUM |
TTQY | Terminal Type And Quantity | 2 SCREW |
CPRQ | Reset Method | MANUAL |
CXCY | Part Name Assigned By Controlling Agency | MAGNETIC CIRCUIT BREAKER, BX STYLE, ONE HANDLE PER UNIT, ROCKER, ACCIDENTAL-OFF PROTECTION, 1 POLE, SERIES, 50/60 HZ MOTOR START |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 1000.0 SINGLE LOCATION |
FEAT | Special Features | BX STYLE HAS FLAT ROCKER ACTUATOR WITH ACCIDENTAL ACTUATION PROTECTION |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AJEC | Boss Height | 0.439 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.859 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.490 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.490 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 150.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.