Thank you for taking interest in Sensata Technologies Inc part number 209-1-1-61F-4-8-5, which is listed with the NSN 5925-01-462-4827 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 209-1-1-61F-4-8-5, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-462-4827. For example, you can browse other Sensata Technologies Inc components that were produced under CAGE Code 81541 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 209-1-1-61F-4-8-5 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-462-4827 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014624827 | P | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
209-1-1-61F-4-8-5 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.750 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC SINGLE LOCATION |
FREQ | Frequency In Hertz | 50.0 SINGLE LOCATION OR 60.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 1.026 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.220 INCHES NOMINAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 3.550 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 5.125 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 3.550 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.600 MINIMUM AT 125 PCT SINGLE LOCATION AND 5.000 MAXIMUM AT 125 PCT SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |