Thank you for taking interest in Sensata Technologies Inc part number AP-17-1-51-203, which is listed with the NSN 5925-01-407-2549 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number AP-17-1-51-203, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-407-2549. For example, you can browse other Sensata Technologies Inc components that were produced under CAGE Code 81541 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number AP-17-1-51-203 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-407-2549 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014072549 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP-17-1-51-203 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 500.0 DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
ADAT | Body Width | 1.250 INCHES MAXIMUM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
CQJX | Nominal Thread Size | 0.375 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
ADAQ | Body Length | 1.500 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
THSD | Thread Series Designator | UNEF |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.090 MINIMUM AT 200 PCT ALL LOCATIONS AND 60.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.