Thank you for taking interest in Sensata Technologies Inc part number APL-11-1REC2-64-103-MA, which is listed with the NSN 5925-01-307-2007 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number APL-11-1REC2-64-103-MA, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-307-2007. For example, you can browse other Sensata Technologies Inc components that were produced under CAGE Code 81541 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number APL-11-1REC2-64-103-MA and other desired offerings on Aerospace Spare.
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM |
CSSX | Switch Current Rating And Type In Amps | 10.0 AC AND 3.0 DC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 7.400 OUNCES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
BBRJ | Special Handling Feature | MAGNETIC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
ADAT | Body Width | 1.500 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND 50.0 DC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | ISO S |
AJWX | Mounting Surface To Terminal End Distance | 2.475 INCHES NOMINAL |
ADAQ | Body Length | 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM |
CQQR | Thread Pitch In Millimeters | 0.5 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 1.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CRTK | Switch Terminal Type | QUICK DISCONNECT, MALE |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CQJX | Nominal Thread Size | 3.0 MILLIMETERS |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote