Thank you for taking interest in Schneider Electric Gmbh part number BACK-UPS PRO-650, which is listed with the NSN 6130-01-462-4226 and a product description of “Power Supply.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number BACK-UPS PRO-650, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Power Supply part with the NSN 6130-01-462-4226. For example, you can browse other Schneider Electric Gmbh components that were produced under CAGE Code 0MG77 or listings that belong to FSC 6130 Converters Electrical Non Rotating with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number BACK-UPS PRO-650 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-462-4226 Item PartTypeName: POWER SUPPLY | 6130 | 014624226 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
BACK-UPS PRO-650 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
FEAT | Special Features | PROGRAMMING TO AUTOMATICALLY INCREASE OUTPUT UP TO 30 PERCENT WHEN INPUT FALLS BETWEEN 81 VAC TO 106 VAC; AUTOMATICALLY DECREASES OUTPUT UP TO 15 PERCENT WHEN INPUT IS BETWEEN 127 VAC AND 143 VAC; OVERLOAD PROTECTION ON BATTERY-INTERNAL CURRENT LIMITING AND ON LINE CIRCUIT BREAKER; MODEM/10 BASE-T/100 BASE-TX NETWORK CABLE PORT USING SINGLE LINE (2 WIRE, RJ11) OR NETWORK (UTP, RJ45) COMPATIBLE JACKS; BATTERY IS USER REPLACEABLE, HOT SWAPPABLE, SEALED, AND MAINTENANCE FREE; 14 DAY AUTO SELF TEST OF ALL INTERNAL COMPONENTS; LEDS INDICATE WHEN ON LINE, ON BATTERY, UPS OVERLOAD, AND REPLACE BATTERY; ALARMS FOR ON BATTERY, LOW BATTERY, AND UPS OVERLOAD; DATA SAVING UNATTENDED SHUTDOWN, ADVANCED POWER MANAGEMENT AND DIAGNOSTIC SOFTWARE INCLUDED; DB 9 SERIAL INTERFACE PORT; OUTPUT VOLTAGE ON BATTERY IS STEPPED APPROXIMATION TO SINE WAVE OUTPUT AT 115 VAC PLUS OR MINUS 8 PERCENT |
CXMN | Battery Switching Time | TWO MILLISECONDS |
CBBL | Features Provided | BATTERY CHARGER AND CIRCUIT BREAKER AND CURRENT REGULATOR CIRCUIT AND EMI FILTER AND INDICATOR LIGHT AND OVER VOLTAGE PROTECTOR AND PROGRAMMABLE |
APTS | Output Frequency Rating | 49.9 HERTZ MINIMUM SINGLE POWER OUTPUT AND 60.1 HERTZ MAXIMUM SINGLE POWER OUTPUT |
APTQ | Input Frequency Rating | 47.5 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
CXMX | Battery Power Supply Emergency Operating Time | 6 |
ABKW | Overall Height | 6.600 INCHES NOMINAL |
ABMK | Overall Width | 4.700 INCHES NOMINAL |
CWWB | Battery Recovery Time | 180 |
CWWJ | Program Compatibility | APPLE, IBM COMPATIBLE OR UNIX PERSONAL COMPUTERS |
ANPM | Input Phase | SINGLE SINGLE OPERATING POWER RQMT |
AKWC | Electrical Power Source Relationship | OPERATING |
BGHX | Output Control Quantity | 2 SINGLE POWER OUTPUT |
MRC | Decoded Requirement | Clear Text Reply |
BGQR | Output Wattage Rating | 410.0 WATTS MAXIMUM SINGLE POWER OUTPUT |
AKAE | Maximum Operating Altitude Rating | 10000.0 FEET |
CWGW | Power Supply Output Current/Voltage Characteristics | LIMITING VOLTAGE SINGLE POWER OUTPUT |
CWHY | Battery Feature And Type | RECHARGEABLE LEAD ACID CELL |
APPA | Output Voltage Rating | 115.0 AC VOLTS NOMINAL SINGLE POWER OUTPUT |
ABHP | Overall Length | 14.500 INCHES NOMINAL |
CWGH | Output Current Rating | 650.0 AC VOLT-AMPERE MAXIMUM SINGLE POWER OUTPUT |
CXNJ | Power Supplies Programmed Per System | 2 |
AYNH | Operating Ambient Temp Range | +32.0/+104.0 DEG FAHRENHEIT |
CWGN | Output Phase | SINGLE SINGLE POWER OUTPUT |
BGHY | Output Control Type | VOLTAGE RANGE SINGLE POWER OUTPUT |
APNX | Input Voltage Rating | 120.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT |
CWHF | Output Connection Quantity | 6 SINGLE POWER OUTPUT |
CWHJ | Output Connection Type | RECEPTACLE, ELECTRICAL SINGLE POWER OUTPUT |
CWHQ | Input Connection Type | CONNECTOR, PLUG SINGLE OPERATING POWER RQMT |
CWHT | Input Connection Quantity | 2 SINGLE OPERATING POWER RQMT |
AMQY | Installation Design | CABINET WITH COMPLETE HARDWARE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.