Thank you for taking interest in Raytheon Company part number 533257-112, which is listed with the NSN 5925-00-476-7997 and a product description of “Circuitbreaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 533257-112, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuitbreaker part with the NSN 5925-00-476-7997. For example, you can browse other Raytheon Company components that were produced under CAGE Code 96214 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 533257-112 and other desired offerings on Aerospace Spare.
MRC | Criteria | Characteristic |
---|---|---|
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.594 INCHES MINIMUM AND |
CQXF | Inclosure Protection Type For Which Designed | HERMETICALLY SEALED AND |
BBRJ | Special Handling Feature | MAGNETIC |
MRC | Decoded Requirement | Clear Text Reply |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
AEFP | Nonturn Device Radius | 0.656 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
TTQY | Terminal Type And Quantity | 6 WIRE HOOK |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEFP | Nonturn Device Radius | 0.594 INCHES MINIMUM AND |
AEFQ | Nonturn Device Length | 0.063 INCHES MINIMUM AND |
AEFS | Nonturn Device Diameter | 0.171 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRX | Actuator Position Designation | AT POLE TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPRW | Actuator Function | TRIP-RESET |
AAJE | Thread Pitch Diameters | 0.3503 TO 0.3537 INCHES |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
AEFN | Nonturn Device Location | AT 3 OCLOCK AND |
AEFN | Nonturn Device Location | AT 9 OCLOCK |
AEFQ | Nonturn Device Length | 0.125 INCHES MAXIMUM |
AEFS | Nonturn Device Diameter | 0.109 INCHES MINIMUM AND |
ADAQ | Body Length | 1.500 INCHES MAXIMUM |
CQJX | Nominal Thread Size | 0.375 INCHES |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.906 INCHES MAXIMUM |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.656 INCHES MAXIMUM |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.844 INCHES MINIMUM AND |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
ADAT | Body Width | 1.875 INCHES MAXIMUM |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.900 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 4.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
THSD | Thread Series Designator | UNEF |
CQXF | Inclosure Protection Type For Which Designed | VIBRATION RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote