Thank you for taking interest in Raytheon Company part number 271-1290P2, which is listed with the NSN 5925-00-027-2764 and a product description of “Circuitbreaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 271-1290P2, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuitbreaker part with the NSN 5925-00-027-2764. For example, you can browse other Raytheon Company components that were produced under CAGE Code 49956 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 271-1290P2 and other desired offerings on Aerospace Spare.
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.25 AMPERES AC SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 115.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRX | Actuator Position Designation | AT POLE ONE |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPRW | Actuator Function | TRIP-RESET |
THSD | Thread Series Designator | UNC |
CQJX | Nominal Thread Size | 0.190 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.471 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.938 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 25.000 NOMINAL AT 125 PCT SINGLE LOCATION AND 8.000 NOMINAL AT 130 PCT SINGLE LOCATION AND 2.5000 NOMINAL AT 138 PCT SINGLE LOCATION |
CMLP | Thread Quantity Per Inch | 32 |
CPRQ | Reset Method | MANUAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |