Request a Quote on Ortho Clinical Diagnostics Inc Part VITROS-DT60-II with the NSN 6630-01-332-7886

Part Number: VITROS-DT60-II
Alternate P/N: VITROSDT60II
NIIN: 013327886
Item Name : Analyzer Clinical C
CAGE Code: 03KD1
FSG: 66 Instruments and Laboratory Equipment
Country : USA
NCB Code : 01

Thank you for taking interest in Ortho Clinical Diagnostics Inc part number VITROS-DT60-II, which is listed with the NSN 6630-01-332-7886 and a product description of “Analyzer Clinical C.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.

Note : We Will Not Share Your Information To Any Third Parties.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/customer-terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Upload RFQ SHEET

Alongside part number VITROS-DT60-II, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Analyzer Clinical C part with the NSN 6630-01-332-7886. For example, you can browse other Ortho Clinical Diagnostics Inc components that were produced under CAGE Code 03KD1 or listings that belong to FSC 6630 Chemical Analysis Instruments with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number VITROS-DT60-II and other desired offerings on Aerospace Spare.

Characteristics Data of NSN 6630-01-332-7886, 6630013327886

MRCCriteriaCharacteristic
DPTHDepth14.000 INCHES
CBBLFeatures ProvidedBATCH PROCESSING AND DATA ENTRY KEYBOARD AND DISCRETE PROCESSING AND INTEGRAL PRINTER AND RS232 PORT AND STAT PROCESSING
ELECVoltage In Volts110.0 AND 240.0
MRCDecoded RequirementClear Text Reply
ACDCCurrent TypeAC
CYFVMethod Of AnalysisCOLORIMETRIC AND KINETIC ENZYME/RATE TEST AND POTENTIOMETRIC/ION SELECTIVE ELECTRODE
CYFZTest Sample/Specimen Size12.0 MICROLITERS
CYGDThroughput Per Hour50 SAMPLES/SPECIMENS MINIMUM
ACZBFrequency Rating50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL
CYFWWavelength Range Data Non-AvailabilityNOT INCLUDED AS AN ESSENTIAL CHARACTERISTIC IN THE SPECIFICATION/CID COVERING THIS STANDARD NSN
CYFYAnalysis Test/Measurement RangeALBUMIN 3-5 G/DL; AMYLASE 5-900 U/L; CREATINE 0.1-15 MG/DL; GLUCOSE 20-450 MG/DL; UREA NITROGEN 1-100 MG/DL; PHOSPHORUS 0.5-13 MG/DL; TOTAL BILIRUBIN 0.1-20 MG/DL; TOTAL PROTEIN 2-11 G/DL; ASPARTATE AMINOTRANSFERASE (AST) 4-950 U/L; ALANINE AMINOTRANSFERASE (ALT) 3-950 U/L; CREATINEKINASE (CK) 20-1600 U/L; CALCIUM 3-15 MG/DL; SODIUM 95-215 MMO1/L; POTASSIUM 1-11 MMQ1/L; CHLORIDE 65-140 MMO1/L; CARBON DIOXIDE 5-50 MMO1/L
CYGETest Sample/Specimen Delivery DevicePIPET, HANDHELD AUTOMATIC
AKYDAccessory Components And QuantityPIPETTE(S)
FEATSpecial FeaturesDRY CHEMICAL TECHNOLOGY; SOLID STATE
AQXYTest Type For Which DesignedALBUMIN; AMYLASE; CREATININE; GLUCOSE; UREA NITROGEN; PHOSPHORUS; TOTAL BILIRUB; TOTAL PROTEIN; ASPARTATE AMINOTRANSFERASE,(AST); ALANINE AMINOTRANSFERASE,(ALT); CREATINE KINASE (CK); CALCIUM; SODIUM; POTASSIUM; CHLORIDE; CARBON DIOXIDE
ABRNHeight7.000 INCHES
WDTHWidth42.000 INCHES
CYFXElectrode TypeCALCIUM/CA++ AND CARBON DIOXIDE/CO2 AND CHLORIDE/CL- AND POTASSIUM/K+ AND SODIUM/NA+

Related NSN Components of VITROS DT60 II

A Complete NSN Part Purchasing Platform

  • AS9120B and ISO 9001:2015
  • Aviation Suppliers Association Member
  • FAA AC 0056B Accredited
  • AS 6081:2012 Certification
  • ESD S20.20-2014 Certification

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top