Thank you for taking interest in Nikkiso Pumps America Inc part number CJIT 8758-02014, which is listed with the NSN 4320-01-407-7563 and a product description of “Pump Unit Reciproca.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number CJIT 8758-02014, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Pump Unit Reciproca part with the NSN 4320-01-407-7563. For example, you can browse other Nikkiso Pumps America Inc components that were produced under CAGE Code 58442 or listings that belong to FSC 4320 Power And Hand Pumps with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number CJIT 8758-02014 and other desired offerings on Aerospace Spare.
MRC | Criteria | Characteristic |
---|---|---|
AHYV | Maximum Discharge Flow Rate | 0.08 GALLONS PER MINUTE |
ELEC | Voltage In Volts | 115 |
ASAZ | Discharge Connection Thread Size And Series/Type Designator | 0.375-18 NPT |
AAYT | Intake Connection Quantity | 1 |
AHYW | Discharge Pressure | 100.0 POUNDS PER SQUARE INCH GAGE |
AHZP | Volume Control Type | HYDRAULIC CYLINDER |
AAYW | Discharge Connection Type | THREADED EXTERNAL |
ASWT | Intake Connection Thread Size And Series/Type Designator | 0.375-18 NPT |
AHZA | Pumping Element Operating Position | HORIZONTAL |
AAXS | Prime Mover Cooling Medium | AIR |
AHZN | Reciprocating Stroke Type | VARIABLE |
AHZQ | Control Location | RIGHT SIDE |
FREQ | Frequency In Hertz | 60 |
AHZJ | Pump Reciprocating Design | SINGLE ACTING |
FAAZ | Phase | SINGLE |
AAXH | Prime Mover Quantity | 1 |
MRC | Decoded Requirement | Clear Text Reply |
CSYL | Prime Mover Power Rating | 0.25 HORSEPOWER |
AENC | Pump Quantity | 1 |
FEAT | Special Features | FIELD ADJUSTABLE HYDRAULIC RELIEF VALVE; AUTOMATIC AIR VENTING ON EACH STROKE, SELF-COMPENSATING HYDRAULIC SYSTEM, LARGE SINGLE BALL CHECK |
ACDC | Current Type | AC |
AAYU | Intake Connection Type | THREADED EXTERNAL |
AKDJ | Prime Mover Type | ELECTRIC MOTOR |
AAYV | Discharge Connection Quantity | 1 |
AAXX | Mounting Type | BASE |
AAXZ | Cylinder Quantity | 1 |
AENG | Pumping Element Type | DIAPHRAGM |
AENK | Cooling Method | AIR TO AIR COOLED |
AGAV | End Item Identification | W/S, USNS HENRY J. KAISER |
AMPS | Current Rating In Amps | 2.4 |
AKNA | Inclosure Type | FULLY INCLOSED |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.