Thank you for taking interest in Microwave Development Laboratories part number 90PK389-1, which is listed with the NSN 5985-00-102-4200 and a product description of “Waveguideassembly.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 90PK389-1, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Waveguideassembly part with the NSN 5985-00-102-4200. For example, you can browse other Microwave Development Laboratories components that were produced under CAGE Code 01456 or listings that belong to FSC 5985 Antennas Waveguides and Related Equipment with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 90PK389-1 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-00-102-4200 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 001024200 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2546068-1 | 6 | 2 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM FIRST FLANGE AND 0.903 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM FIRST FLANGE AND 0.403 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.407 INCHES MINIMUM FIRST FLANGE AND 1.437 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.422 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY AND 0.172 INCHES MAXIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.05 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.994 INCHES MINIMUM AND 1.006 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.897 INCHES MINIMUM AND 0.903 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.397 INCHES MINIMUM AND 0.403 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.494 INCHES MINIMUM AND 0.506 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTFD | WAVEGUIDE LENGTH | 1.329 FEET NOMINAL |
FEAT | SPECIAL FEATURES | TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SINGLE CONNECTION FACILITY |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.