Thank you for taking interest in Lockheed Martin Corporation part number 17-19097-1, which is listed with the NSN 5985-01-271-7255 and a product description of “Waveguide Assembly.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 17-19097-1, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Waveguide Assembly part with the NSN 5985-01-271-7255. For example, you can browse other Lockheed Martin Corporation components that were produced under CAGE Code 80070 or listings that belong to FSC 5985 Antennas Waveguides and Related Equipment with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 17-19097-1 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-271-7255 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 012717255 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
17-19097-1 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJD | THREAD CLASS | 2B SECOND FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE SINGLE CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 3 |
AHSX | FLANGE INSIDE WIDTH | 0.279 INCHES MINIMUM FIRST FLANGE AND 0.281 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.279 INCHES MINIMUM SECOND FLANGE AND 0.281 INCHES MAXIMUM SECOND FLANGE |
AHSX | FLANGE INSIDE WIDTH | 0.362 INCHES MINIMUM THIRD FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.139 INCHES MINIMUM FIRST FLANGE AND 0.141 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.139 INCHES MINIMUM SECOND FLANGE AND 0.141 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.222 INCHES MINIMUM THIRD FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.735 INCHES MINIMUM FIRST FLANGE AND 0.765 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.735 INCHES MINIMUM SECOND FLANGE AND 0.765 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 0.745 INCHES MINIMUM THIRD FLANGE AND 0.755 INCHES MAXIMUM THIRD FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.735 INCHES MINIMUM FIRST FLANGE AND 0.765 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.735 INCHES MINIMUM SECOND FLANGE AND 0.765 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 0.745 INCHES MINIMUM THIRD FLANGE AND 0.755 INCHES MAXIMUM THIRD FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 0.485 INCHES MINIMUM FIRST FLANGE AND 0.515 INCHES MAXIMUM FIRST FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 0.485 INCHES MINIMUM SECOND FLANGE AND 0.515 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.182 INCHES MINIMUM THIRD FLANGE AND 0.192 INCHES MAXIMUM THIRD FLANGE |
AHTD | FLANGE DEPTH | 0.195 INCHES MINIMUM FIRST FLANGE AND 0.225 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.195 INCHES MINIMUM SECOND FLANGE AND 0.225 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.116 INCHES MINIMUM THIRD FLANGE SINGLE CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AHTX | INSERTION LOSS IN DECIBELS | 0.25 |
CMLP | THREAD QUANTITY PER INCH | 40 FIRST FLANGE SINGLE CONNECTION FACILITY |
CMLP | THREAD QUANTITY PER INCH | 40 SECOND FLANGE SINGLE CONNECTION FACILITY |
CQGM | MAXIMUM OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.358 INCHES MINIMUM AND 0.362 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SECOND FLANGE SINGLE CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.279 INCHES MINIMUM AND 0.282 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.139 INCHES MINIMUM AND 0.142 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.218 INCHES MINIMUM AND 0.222 INCHES MAXIMUM |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 3.910 INCHES MINIMUM AND 3.970 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE THIRD FLANGE SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | CHOKE TYPE SECOND FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE THIRD FLANGE |
CWBG | WAVEGUIDE OFFSET DISTANCE | 2.920 INCHES MINIMUM AND 2.980 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | FIRST AND SECOND FLANGE INSTALLED DIAMETRICALLY OPPOSITE EACH OTHER |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY SINGLE TUBING SEGMENT AND FLANGE |
PMLC | PRECIOUS MATERIAL AND LOCATION | EXTERNAL SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
SFTT | SURFACE TREATMENT | SILVER SINGLE TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | BEND TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SINGLE CONNECTION FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE SINGLE CONNECTION FACILITY |
ZZZV | FSC APPLICATION DATA | RADAR EQUIPMENT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote