Thank you for taking interest in Lockheed Martin Corporation part number 2380594-4, which is listed with the NSN 5945-00-052-4177 and a product description of “Relay Electromagnetic.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 2380594-4, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Relay Electromagnetic part with the NSN 5945-00-052-4177. For example, you can browse other Lockheed Martin Corporation components that were produced under CAGE Code 56232 or listings that belong to FSC 5945 Relays and Solenoids with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 2380594-4 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-052-4177 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 000524177 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P56A1P6AS3 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.208 INCHES MINIMUM AND 1.218 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.995 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.120 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.880 INCHES MINIMUM AND 0.890 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.390 INCHES MINIMUM AND 0.400 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.094 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.102 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.92 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
AYSC | PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 0.434 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.006 SECONDS MAXIMUM FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.01 SECONDS MAXIMUM FIXED OPERATE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 50.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC INDUCTIVE LOAD AND 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 50.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |