Thank you for taking interest in General Dynamics Satcom part number CTR015, which is listed with the NSN 6120-01-469-9388 and a product description of “Transformer Power.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number CTR015, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Transformer Power part with the NSN 6120-01-469-9388. For example, you can browse other General Dynamics Satcom components that were produced under CAGE Code 1GD22 or listings that belong to FSC 6120 Transformers Distribution and Power Station with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number CTR015 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6120-01-469-9388 Item PartTypeName: TRANSFORMER,POWER | 6120 | 014699388 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CTR015 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | Mounting Hole Diameter | 0.250 INCHES NOMINAL SINGLE GROUP |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CBBL | Features Provided | COLOR CODED LEAD AND PROTECTIVE COVER AND SPECIAL MARKING |
ADAU | Body Height | 1.900 INCHES NOMINAL |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | Winding Operating Current | 0.6 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CRBZ | Winding Operating Current | 0.7 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
ACZF | Maximum Transformer Power Rating | 150.0 VOLT-AMPERE SINGLE COMPONENT |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
FEAT | Special Features | SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66 |
ADAR | Body Outside Diameter | 3.900 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
AKNA | Inclosure Type | FULLY INCLOSED |