Thank you for taking interest in Gems Sensors Inc part number LS208666-1, which is listed with the NSN 5930-00-014-1703 and a product description of “Switch Liquid Level.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number LS208666-1, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Switch Liquid Level part with the NSN 5930-00-014-1703. For example, you can browse other Gems Sensors Inc components that were produced under CAGE Code 04034 or listings that belong to FSC 5930 Switches with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number LS208666-1 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-014-1703 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 000141703 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LS208666-1 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 25.625 INCHES NOMINAL |
ABJP | POWER CABLE LENGTH | 300.000 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 110.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | 220.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ADAV | OVERALL DIAMETER | 3.500 INCHES NOMINAL |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | CABLE |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 45.0 MILLIAMPERES NOMINAL LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 110.0 VOLTS |
AWAE | FLOAT QUANTITY | 2 |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | 0.250IN.-20 THD4HOLES EQ.SPACED ON A 2.437IN.DIA.B.C. |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 99.0 MILLIAMPERES NOMINAL LOAD |
BJKD | CONTACT ARRANGEMENT | NORMALLY OPEN DRY,2 POLE SINGLE THROW |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | HYDRAULIC OIL AND LUBRICATING OIL AND SEA WATER AND VARIOUS FUELS |
BJKN | FLOAT EFFECTIVE TRAVEL | 19.437 INCHES NOMINAL |
BJKP | MOUNTING DIMENSIONS | MTD BY 4 THREADED HOLES 0.250-20 SPACED EQ ON 2.437IN.DIA. B.C. |
BJKQ | TANK INSERTION LENGTH | 22.500 INCHES NOMINAL |
FAAZ | PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
FAAZ | PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |