Thank you for taking interest in Ge Kaye Instruments Inc part number HTR-400, which is listed with the NSN 6685-01-483-1283 and a product description of “Control Humidity.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number HTR-400, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Control Humidity part with the NSN 6685-01-483-1283. For example, you can browse other Ge Kaye Instruments Inc components that were produced under CAGE Code 17466 or listings that belong to FSC 6685 Pressure Temperature And Humidity Measuring And Controlling Instruments with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number HTR-400 and other desired offerings on Aerospace Spare.
MRC | Criteria | Characteristic |
---|---|---|
FEAT | SPECIAL FEATURES | ITEM AKA: DRY WELL TEMPERATURE REFERENCE; WGT: 18 LBS; DIM: 12.5"" DEPTH; OPERATING TEMPERATURE: 5 - 50 DEG C;SET POINT ACCURACY: +/- 0.2 DEG C TO 300 DEG C, +/- 0.3 DEG C AT 400 DEG C; SETPOINT STABILITY +/- 0.02 DEG C/DAY TO 300 DEG C, +/- 0.05 DEG C/DAY TO 400 DEG C; DISPLAY RESOLUTION +/- 0.01 DEG C OR F; DISPLAY TYPE: LED, CENTIGRADE OR FAHR.; TYPICAL WARM-UP TIME: 5 MIN AMBIENT TO 90 DEG C, 3 MIN: 90 TO 125 DEG C, 25 MIN: AMBIENT TO 350 DEG C; TYPICAL COOL DOWN TIMES: 20 MIN: 125 TO 90 DEG C, 15 MIN: 350 TO 270 DEG C; FAULT PROTECTION: SENSOR BURNOUT PROTECTION, OVER TEMPERATURE THERMAL CUTOUT, ELECTRICAL FUSE: 115V, 6A; 230V, 3A; WELL DIMENSIONS: 2 REFERENCE WELLS AT 6.7MM (0.265"") DIA. X 127MM (0.265"") DIA. X 127MM (5"") DEEP 8 CALIBRATION WELLS AT 9MM (0.354"") DIA. X 155MM (6.1"") DEEP; CALIBRATION WELL CAPACITY: 24 OR 32 DEPENDING ON WIRE SIZE |
CHQR | MAXIMUM OVERALL HEIGHT | 13.500 INCHES |
AXGY | MOUNTING METHOD | PLATFORM |
CHQQ | MAXIMUM OVERALL WIDTH | 7.800 INCHES |
CKRD | SENSING ELEMENT TYPE AND LOCATION | THERMOCOUPLE INTERNAL |
AFGA | OPERATING TEMP RANGE | 25.0 TO 400.0 DEG CELSIUS |