Thank you for taking interest in Electronic Transformer Corp part number C12571, which is listed with the NSN 5950-01-063-6149 and a product description of “Transformer Power.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number C12571, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Transformer Power part with the NSN 5950-01-063-6149. For example, you can browse other Electronic Transformer Corp components that were produced under CAGE Code 72149 or listings that belong to FSC 5950 Coils and Transformers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number C12571 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-063-6149 Item PartTypeName: TRANSFORMER,POWER | 5950 | 010636149 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
309465-1 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.550 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.570 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.050 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.070 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.400 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.820 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.850 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 575.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.98 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 10.25 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | SECONDARY TERMINAL SPLIT INTO TWO TERMINALS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB,SOLDER LUG |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.