Thank you for taking interest in Eaton Corporation part number JT3100TV, which is listed with the NSN 5925-01-446-4163 and a product description of “Tripper Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number JT3100TV, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Tripper Circuit Breaker part with the NSN 5925-01-446-4163. For example, you can browse other Eaton Corporation components that were produced under CAGE Code 89946 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number JT3100TV and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-446-4163 Item PartTypeName: TRIPPER,CIRCUIT BREAKER | 5925 | 014464163 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
JT3100TV | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS |
CBBL | Features Provided | ADJUSTABLE TRIP RELEASE |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
CPSF | Adjustable Trip Setting Current Range Per Pole In Amps | +1000.0/+2000.0 AC ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT POLE TWO |
CPLM | Maximum Continuous Load Current Rating Per Pole | 100.0 AMPERES AC ALL LOCATIONS AND 100.0 AMPERES DC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
AGAV | End Item Identification | CIRCUIT BREAKER, PART NUMBER HJD3100V ABOARD 420 FT WAGB COAST GUARD VESSELS |
AKPX | Pole Quantity | 3 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |