Thank you for taking interest in Eaton Corporation part number AM13MG6-7-50VDC5, which is listed with the NSN 5925-01-049-1287 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number AM13MG6-7-50VDC5, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-049-1287. For example, you can browse other Eaton Corporation components that were produced under CAGE Code 74193 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number AM13MG6-7-50VDC5 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-049-1287 Item Description: CIRCUIT BREAKER | 5925 | 010491287 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM13MG6-7-50VDC5 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF AND FUNGUS PROOF |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
AAQL | Body Style | SINGLE POLE TYPE |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.155 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.850 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 7.0 AMPERES DC SINGLE LOCATION |
BBRJ | Special Handling Feature | MAGNETIC |
AFJN | Fragility Factor | MODERATELY RUGGED |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 50.0 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 AC SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
ADAT | Body Width | 0.750 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
CPRX | Actuator Position Designation | AT POLE ONE |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
AJWX | Mounting Surface To Terminal End Distance | 2.611 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
THSD | Thread Series Designator | UNC |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |