Thank you for taking interest in Dresser Rand Company part number W96397T3, which is listed with the NSN 5930-00-498-5922 and a product description of “Switch Pressure.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number W96397T3, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Switch Pressure part with the NSN 5930-00-498-5922. For example, you can browse other Dresser Rand Company components that were produced under CAGE Code 88663 or listings that belong to FSC 5930 Switches with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number W96397T3 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-498-5922 Item PartTypeName: SWITCH,PRESSURE | 5930 | 004985922 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
37329489 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B SINGLE PRESSURE CONNECTION |
AARX | INSIDE DIAMETER | 0.438 INCHES NOMINAL SINGLE CONNECTION |
AASA | THREAD LENGTH | 0.500 INCHES NOMINAL SINGLE PRESSURE CONNECTION |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT |
ABHP | OVERALL LENGTH | 5.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 10.938 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.000 INCHES NOMINAL |
ADAQ | BODY LENGTH | 5.750 INCHES NOMINAL |
ADAU | BODY HEIGHT | 10.313 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.375 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.000 INCHES NOMINAL |
AFDW | SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.062 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AWTN | OPERATING TEMP RATING | 66.0 DEG CELSIUS MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJB | PROOF PRESSURE | 5600.00 POUNDS PER SQUARE INCH GAGE |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
CTYM | CONTACT ADJUSTMENT RANGE | 500.00 TO 5000.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE AND 500.00 TO 5000.00 DEACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT HEX NUT WITH SCALE AND INTERNAL DEACTUATION POINT HEX NUT WITH SCALE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | PLAIN,THREADED INTERNAL SINGLE CONNECTION |
FEAT | SPECIAL FEATURES | LOWER CONTACT LOAD RATING 1.0 AMP DC AND 16.0 AMP AT 115.0 VOLTS |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
STYL | STYLE DESIGNATOR | RECTANGULAR |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote