Thank you for taking interest in Cigentec Inc part number TDC686-025WLG, which is listed with the NSN 5910-01-228-9047 and a product description of “Capacitor Fixed Electrolytic.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number TDC686-025WLG, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Capacitor Fixed Electrolytic part with the NSN 5910-01-228-9047. For example, you can browse other Cigentec Inc components that were produced under CAGE Code 37924 or listings that belong to FSC 5910 Capacitors with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number TDC686-025WLG and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-228-9047 Item PartTypeName: CAPACITOR,FIXED,ELECTROLYTIC | 5910 | 012289047 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TDC686-025WLG | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES,TERMINAL(S) ON ONE ENDW/O MTG FACILITIES,TERMINAL(S) ON ONE ENDW/O MTG FACILITIES,TERMINAL(S) ON ONE END |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.500 INCHES MINIMUM0.500 INCHES MINIMUM0.500 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.400 INCHES MAXIMUM |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.280 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AECE | ANODE TYPE | SOLID |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 68.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 200.0 MICROAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 25.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -20.00/20.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 8.000 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 20.000 MICROAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |