Thank you for taking interest in Carling Technologies Inc part number CA2-B0-16-650-121-C, which is listed with the NSN 5925-01-613-5685 and a product description of “Circuit Breaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number CA2-B0-16-650-121-C, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuit Breaker part with the NSN 5925-01-613-5685. For example, you can browse other Carling Technologies Inc components that were produced under CAGE Code 73559 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number CA2-B0-16-650-121-C and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-613-5685 Item PartTypeName: CIRCUIT BREAKER | 5925 | 016135685 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CA2-B0-16-650-121-C | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 80.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 62.5 ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
CXCY | Part Name Assigned By Controlling Agency | C SERIES, CIRCUIT BREAKER |
CPRQ | Reset Method | MANUAL |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
CPRR | Main Contact Tripping Mechanism Type | NONTRIP FREE |
AJWX | Mounting Surface To Terminal End Distance | 2.723 INCHES NOMINAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 45.0 MINIMUM AT 125 PCT AND 345.0 MAXIMUM AT 125 PCT ALL LOCATIONS |
FEAT | Special Features | USED ON BOATALT 38RP |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |