Thank you for taking interest in Carling Technologies Inc part number CMB 203 11C3B B A 20, which is listed with the NSN 5925-01-591-0205 and a product description of “Circuitbreaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number CMB 203 11C3B B A 20, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuitbreaker part with the NSN 5925-01-591-0205. For example, you can browse other Carling Technologies Inc components that were produced under CAGE Code 73559 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number CMB 203 11C3B B A 20 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-591-0205 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015910205 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CMB-203-11C3B-B-A/20 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
ABMK | Overall Width | 0.571 INCHES NOMINAL |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 5.000 AT 800 PCT PASCAL SINGLE LOCATION AND 12.500 18 STAGE PASCAL SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC SINGLE LOCATION AND 20.0 AMPERES DC SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2500.0 AC SINGLE LOCATION AND 2500.0 DC SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 TAB, SOLDER LUG |
FREQ | Frequency In Hertz | 60.0 SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
CPRT | Manual Actuator Type And Quantity | 1 PUSH BUTTON |
CPRW | Actuator Function | TRIP-RESET |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 1.693 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 125.0 AC SINGLE LOCATION AND 250.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION |
ABHP | Overall Length | 1.379 INCHES NOMINAL |
FEAT | Special Features | BLACK BUTTON IS MARKED "20 AMP" WITH SILVER PRINTING |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 SINGLE LOCATION |