Thank you for taking interest in Bae Systems Inc part number 20007792, which is listed with the NSN 5950-00-509-8431 and a product description of “Transformer Power.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number 20007792, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Transformer Power part with the NSN 5950-00-509-8431. For example, you can browse other Bae Systems Inc components that were produced under CAGE Code 72314 or listings that belong to FSC 5950 Coils and Transformers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number 20007792 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-509-8431 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005098431 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
20007792 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT400.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.875 INCHES NOMINAL5.875 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.750 INCHES NOMINAL4.750 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.938 INCHES NOMINAL3.938 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT8 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY8.75 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY1.25 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY8.75 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY1.25 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY1.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 8 SECONDARY WINDINGS; WINDINGS 5 AND 7 ARE CENTER TAPPED AND THE TAPS ARE CORE PROUNDED AND BROUGHT OUT TO TERMINALS |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 23 WIRE LEAD |