Thank you for taking interest in Airpax Corp part number AP-1-1-51-501, which is listed with the NSN 5925-01-277-1980 and a product description of “Circuitbreaker.” In order to receive procurement options on this particular listing, we ask that you fill out and submit the form provided below with as much information as you can concerning your needs. By supplying our staff with key details on your desired quantity, pricing target, and expedited fulfillment timeframe, we can respond with a quote that has been specifically tailored to your unique specifications. We also ask that you make us aware of any restrictions that you may have as soon as possible, such as if you have a time constraint or are seeking unlisted items.
Note : We Will Not Share Your Information To Any Third Parties.
Alongside part number AP-1-1-51-501, you are encouraged to continue exploring our collection curated catalogs to find additional items that can accompany this Circuitbreaker part with the NSN 5925-01-277-1980. For example, you can browse other Airpax Corp components that were produced under CAGE Code 82415 or listings that belong to FSC 5925 Circuit Breakers with ease on our website, with search tools provided for quick location. Furthermore, our staff is just a call or email away from assisting you with any inquiries or requests, so be sure to get started on the quotation process for part number AP-1-1-51-501 and other desired offerings on Aerospace Spare.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-277-1980 Item PartTypeName: CIRCUIT BREAKER | 5925 | 012771980 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AP-1-1-51-501 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 500.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC SINGLE LOCATION AND 50.0 DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.400 MINIMUM AT 125 PCT SINGLE LOCATION AND 4.000 MAXIMUM AT 125 PCT SINGLE LOCATION AND 0.060 MINIMUM AT 200 PCT SINGLE LOCATION AND 0.600 MAXIMUM AT 200 PCT SINGLE LOCATION AND 0.010 MINIMUM AT 400 PCT SINGLE LOCATION AND 0.200 MAXIMUM A |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION OR 400.0 SINGLE LOCATION |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.