MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AAJD | THREAD CLASS | 2B FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.897 INCHES MINIMUM FIRST FLANGE AND 0.903 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.397 INCHES MINIMUM FIRST FLANGE AND 0.403 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.406 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTB | FLANGE INSIDE DIAMETER | 1.406 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.422 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL SECOND FLANGE SINGLE CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.04 |
AHTX | INSERTION LOSS IN DECIBELS | 0.10 |
CQGM | MAXIMUM OPERATING PRESSURE | 20.0 POUNDS PER SQUARE INCH GAGE |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CHOKE TYPE FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
CTFD | WAVEGUIDE LENGTH | 2.750 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | MTG BRACKET WITH TWO PANEL FASTENER ASSEMBLIES ATTACHED,LOCATED 1.844 IN. FROM CHOKE FLANGE END TO CENTER OFBRACKET |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY SINGLE TUBING SEGMENT |
SFTT | SURFACE TREATMENT | OXIDE FILM ALL FLANGE OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | OXIDE FILM SINGLE TUBING SEGMENT OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SINGLE CONNECTION FACILITY |