MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2B SECOND FLANGE FIRST CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE THIRD TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SECOND TUBING SEGMENT |
AHRW | TUBING TWIST TYPE | STRAIGHT TWIST FIRST TUBING SEGMENT |
AHRX | TUBING TWIST ANGLE IN DEG | 45.0 FIRST TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 0.689 INCHES MINIMUM AND 0.693 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.319 INCHES MINIMUM AND 0.323 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.358 INCHES MINIMUM AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.095 INCHES MINIMUM AND 0.096 INCHES MAXIMUM SECOND FLANGE SECOND CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.096 INCHES NOMINAL FIRST FLANGE SECOND CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.143 INCHES MINIMUM AND 0.149 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.791 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
FEAT | SPECIAL FEATURES | 1ST FLANGE INCLUDES RF/ PRESSURE SEAL W/ FOUR 0.875 IN. LG SCREWS; FLEXIBLE PORTION COVERED W/ MOLDED NEOPRENE OR SILICONE JACKET DEPENDING ON USE |
FLEX | FLEXIBILITY | FLEXIBLE FOURTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
STYL | STYLE DESIGNATOR | FOUR BEND TYPE |
SUPP | SUPPLEMENTARY FEATURES | 1ST TUBING SEGMENT MARKED W/ARROW AND LETTERS AFT |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE FIRST CONNECTION FACILITY |
ZZZV | FSC APPLICATION DATA | RADAR EQUIPMENT |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR DOUBLE RIDGED EXTERNAL,RECTANGULAR |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE FIRST CONNECTION FACILITY |
AHSF | FLANGE QUANTITY | 2 |
AHTA | FLANGE OUTSIDE HEIGHT | 1.358 INCHES MINIMUM AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM FIRST FLANGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.55 |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SECOND FLANGE FIRST CONNECTION FACILITY |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.421 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 THREADED HOLE SECOND FLANGE FIRST CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE SECOND FLANGE SECOND CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CONTACT,DOUBLE RIDGE TYPE FIRST FLANGE |
FLEX | FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY ALL FLANGE |
SFTT | SURFACE TREATMENT | ENAMEL ALL FLANGE OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | ENAMEL FIRST TUBING SEGMENT OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | ENAMEL FOURTH TUBING SEGMENT OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | ENAMEL SECOND TUBING SEGMENT OUTSIDE SURFACES |