MRC | Criteria | Characteristic |
---|
ADYY | Coating Material | RAYCHEM PRECOATING NO. 25, HIGH-PERFORMANCE ADHESIVE NO. S-1048 |
MRC | Decoded Requirement | Clear Text Reply |
CBBL | Features Provided | ADHESIVE COATING |
AFZU | Main Body Inside Diameter | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | First Branch Inside Diameter | 0.310 INCHES MINIMUM AS SUPPLIED |
AFZW | Second Branch Inside Diameter | 0.310 INCHES MINIMUM AS SUPPLIED |
AFZY | Fourth Branch Inside Diameter | 0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZZ | Distance From Intersecting Centerline Of Main Body To End Of Second Branch | 1.400 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAC | First Branch Wall Thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAE | Third Branch Wall Thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
ADZC | Environmental Protection | FLUID RESISTANT |
AGAQ | Angle Between Main Body And First Branch Centerlines In Deg | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAU | Heat Shrinkage Rating In Percent | 50 |
CXCY | Part Name Assigned By Controlling Agency | TRANSITION, 1 TO 4 CABLES |
FLEX | Flexibility | FLEXIBLE |
HUES | Color | BLACK |
AFZU | Main Body Inside Diameter | 0.700 INCHES MINIMUM AS SUPPLIED |
AFZV | First Branch Inside Diameter | 0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | Third Branch Inside Diameter | 0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | Third Branch Inside Diameter | 0.310 INCHES MAXIMUM AS SUPPLIED |
AGAA | Distance From Intersecting Centerline Of Main Body To End Of First Branch | 1.260 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAB | Main Body Wall Thickness | 0.070 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAF | Fourth Branch Wall Thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAG | Distance From Edge Of Main Body To Intersecting Centerlines | 1.420 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
ABJH | Temp Rating | -55.0 DEG CELSIUS AND 120.0 DEG CELSIUS |
AARG | Reliability Indicator | NOT ESTABLISHED |
AFZW | Second Branch Inside Diameter | 0.210 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZY | Fourth Branch Inside Diameter | 0.310 INCHES MINIMUM AS SUPPLIED |
AGAD | Second Branch Wall Thickness | 0.040 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAR | Angle Between Main Body And Second Branch Centerlines In Deg | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
MATT | Material | FLUID RESISTANT MODIFIED ELASTOMER |
AGAV | End Item Identification | PROPULSION SECTION ASSY, RMV; AN/WLD-1(V) MINE HUNTING SYS |
STYL | Style Designator | TRANSITION-1 TO 4 CABLES |