MRC | Criteria | Characteristic |
---|
AFZU | Main Body Inside Diameter | 0.730 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
ADZC | Environmental Protection | FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
FLEX | Flexibility | FLEXIBLE |
FEAT | Special Features | INSIDE ADHESIVE COATED |
MATT | Material | RUBBER, NEOPRENE, RT-501, RAYCLAD TUBES INC |
AFZU | Main Body Inside Diameter | 1.460 INCHES MINIMUM AS SUPPLIED |
AFZW | Second Branch Inside Diameter | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | Third Branch Inside Diameter | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZY | Fourth Branch Inside Diameter | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAA | Distance From Intersecting Centerline Of Main Body To End Of First Branch | 2.570 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAD | Second Branch Wall Thickness | 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAF | Fourth Branch Wall Thickness | 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAQ | Angle Between Main Body And First Branch Centerlines In Deg | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAR | Angle Between Main Body And Second Branch Centerlines In Deg | 10.0 NOMINAL AS SUPPLIED |
MRC | Decoded Requirement | Clear Text Reply |
HUES | Color | BLACK |
CQBC | Minimum Tensile Strength | 1500 POUNDS PER SQUARE INCH |
AFZV | First Branch Inside Diameter | 0.380 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | First Branch Inside Diameter | 0.700 INCHES MINIMUM AS SUPPLIED |
AFZX | Third Branch Inside Diameter | 0.700 INCHES MINIMUM AS SUPPLIED |
AFZY | Fourth Branch Inside Diameter | 0.700 INCHES MINIMUM AS SUPPLIED |
AGAB | Main Body Wall Thickness | 0.120 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAC | First Branch Wall Thickness | 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAG | Distance From Edge Of Main Body To Intersecting Centerlines | 2.950 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAQ | Angle Between Main Body And First Branch Centerlines In Deg | 10.0 NOMINAL AS SUPPLIED |
ABJH | Temp Rating | -55.0 DEG CELSIUS |
AFZW | Second Branch Inside Diameter | 0.700 INCHES MINIMUM AS SUPPLIED |
AFZZ | Distance From Intersecting Centerline Of Main Body To End Of Second Branch | 2.830 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAE | Third Branch Wall Thickness | 0.070 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAR | Angle Between Main Body And Second Branch Centerlines In Deg | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AARG | Reliability Indicator | NOT ESTABLISHED |
STYL | Style Designator | TRANSITION-1 TO 4 CABLES |