Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 00-421-8356 (004218356) |
NCB Code | USA (00) |
Manufacturer | Raytheon Company |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
429-5072-001 | raytheon company | transformer power | 97871 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 8.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 8.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP8.510 INCHES MAXIMUM SINGLE MOUNTIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.365 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.365 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.385 INCHES MAXIMUM SINGLE MOUNTIN |
ABTB | MOUNTING HOLE DIAMETER | 0.282 INCHES MINIMUM SINGLE GROUP AND 0.282 INCHES MINIMUM SINGLE GROUP AND 0.344 INCHES MAXIMUM SINGLE GROUP0.344 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SIX PHASE SINGLE COMPONENTTHREE PHASE TO SIX PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENTINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 10.060 INCHES MAXIMUM10.060 INCHES MAXIMUM |
ADAT | BODY WIDTH | 7.560 INCHES MAXIMUM7.560 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 5.500 INCHES MAXIMUM5.500 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 14.7 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES AC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 16.3 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 215.2 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY499.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 499.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 29.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 34.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.15 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY13.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.15 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 29.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 13.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY34.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 30 THREADED STUD |
Relevant Components for NSN - 5950-00-421-8356, 5950004218356 | ||||
5975-01-629-6429 (5975016296429) | 5998-01-305-2341 (5998013052341) | 5930-01-584-0809 (5930015840809) | 5962-01-210-3065 (5962012103065) | |
5905-00-175-4284 (5905001754284) | 5950-01-458-0903 (5950014580903) | 5920-01-490-0904 (5920014900904) | 5998-01-475-9891 (5998014759891) | |
5995-01-575-7529 (5995015757529) | 5962-01-310-7304 (5962013107304) | 5935-01-240-1468 (5935012401468) | 5995-01-374-0247 (5995013740247) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote