MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 1.280 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.800 INCHES MINIMUM FIRST MOUNTING FACILITY AND 0.820 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 0.810 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.810 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.123 INCHES MINIMUM FIRST MOUNTING FACILITY AND 0.143 INCHES MAXIMUM FIRST MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AGAV | END ITEM IDENTIFICATION | MPCD |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 90.0 OHMS MINIMUM SINGLE WINDING AND 110.0 OHMS MAXIMUM SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SECOND MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE FIRST MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 0.840 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE FIRST MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 161.0 MILLIAMPERES DC SINGLE WINDING |
CRXH | TIME DELAY | 0.006 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.062 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.078 INCHES MAXIMUM FIRST MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC MOTOR LOAD AND 2.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 3.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
FEAT | SPECIAL FEATURES | FAILURE RATE M IS 1.0 PERCENT PER 10,000 CYCLES. |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-83536 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-83536/6 GOVERNMENT SPECIFICATION |