Item Name | Relay Electromagnetic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 01-020-6263 (010206263) |
NCB Code | USA (01) |
Manufacturer | Navair And Navsea Managed, Allied Controls Inc |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
3176731 | navair and navsea managed | relay electromagnetic | 10001 | RFQ |
P0HR-6D-26-5VDC | allied controls inc | relay electromagnetic | 02288 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.844 INCHES MINIMUM AND 1.906 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.344 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.406 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.156 INCHES MINIMUM AND 3.218 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.844 INCHES MINIMUM AND 1.906 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 230.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | CUBIC MEASURE | 11.690 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 0.01 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.04 SECONDS NOMINAL FIXED OPERATE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.406 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.468 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC INDUCTIVE LOAD AND 6.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 29.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
Relevant Components for NSN - 5945-01-020-6263, 5945010206263 | ||||
5975-01-629-6429 (5975016296429) | 5998-01-305-2341 (5998013052341) | 5930-01-584-0809 (5930015840809) | 5962-01-210-3065 (5962012103065) | |
5905-00-175-4284 (5905001754284) | 5950-01-458-0903 (5950014580903) | 5920-01-490-0904 (5920014900904) | 5998-01-475-9891 (5998014759891) | |
5995-01-575-7529 (5995015757529) | 5962-01-310-7304 (5962013107304) | 5935-01-240-1468 (5935012401468) | 5995-01-374-0247 (5995013740247) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote