MRC | Criteria | Characteristic |
---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF AND VIBRATION RESISTANT AND WATERTIGHT |
ABHP | OVERALL LENGTH | 5.188 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.687 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
AEVU | BULB LENGTH | 3.000 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL |
AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
PRMT | PRECIOUS MATERIAL | SILVER |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | 5.00/35.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
STYL | STYLE DESIGNATOR | RECTANGULAR |