Item Name | Switch Pressure |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-838-0826 (008380826) |
NCB Code | USA (00) |
Manufacturer | Ellis And Watts International Llc, Johnson Controls Inc, Trane Co The |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
NC4-8 | ellis and watts international llc | switch pressure | 98437 | RFQ |
210AP20 | johnson controls inc | switch pressure | 92578 | RFQ |
10P7 | johnson controls inc | switch pressure | 92578 | RFQ |
210AP60AN | johnson controls inc | switch pressure | 92578 | RFQ |
P20DA10 | johnson controls inc | switch pressure | 92578 | RFQ |
TYPE210AP60AN | johnson controls inc | switch pressure | 92578 | RFQ |
210AP20AN4401 | johnson controls inc | switch pressure | 92578 | RFQ |
4410-8814-1 | trane co the | switch pressure | 60532 | RFQ |
CNT209 | trane co the | switch pressure | 60532 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 3.313 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
CBBL | FEATURES PROVIDED | AUTOMATIC RESET |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 360.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 450.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 90.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR W/BRACKET |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABHP | OVERALL LENGTH | 2.875 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
AXGY | MOUNTING METHOD | BASE AND THREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL THREADED HOLE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CTHF | CONTACT LOAD CURRENT RATING | 14.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 7.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
Relevant Components for NSN - 5930-00-838-0826, 5930008380826 | ||||
5975-01-629-6429 (5975016296429) | 5998-01-305-2341 (5998013052341) | 5930-01-584-0809 (5930015840809) | 5962-01-210-3065 (5962012103065) | |
5905-00-175-4284 (5905001754284) | 5950-01-458-0903 (5950014580903) | 5920-01-490-0904 (5920014900904) | 5998-01-475-9891 (5998014759891) | |
5995-01-575-7529 (5995015757529) | 5962-01-310-7304 (5962013107304) | 5935-01-240-1468 (5935012401468) | 5995-01-374-0247 (5995013740247) | |