MRC | Criteria | Characteristic |
---|
THSD | THREAD SERIES DESIGNATOR | UNC |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
ADAQ | BODY LENGTH | 1.531 INCHES MINIMUM AND 1.562 INCHES MAXIMUM |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
FEAT | SPECIAL FEATURES | MOUNTING HARDWARE INCLUDED; W/S - SEAWOLF CLASS SSN 23 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
CBBL | FEATURES PROVIDED | HIGH INRUSH PROTECTION |
ABXD | BUSHING LENGTH | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | GENERAL PURPOSE |
AKPX | POLE QUANTITY | 2 |
PKWT | III UNPACKAGED UNIT WEIGHT | 100.0 GRAMS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC ALL LOCATIONS |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | AUX CARGO CONTROL & INDICATION PANEL A&D |
SR-1 | SPEC/STD CONTROLLING DATA | |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39019/04-339S |
ADTV | CASE MATERIAL | METAL |
CMLP | THREAD QUANTITY PER INCH | 32 |
ADAT | BODY WIDTH | 1.250 INCHES MINIMUM AND 1.281 INCHES MAXIMUM |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-M39019/4 GOVERNMENT SPECIFICATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC AND 20.0 AMPERES DC ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | SCREW |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES MINIMUM AND 0.906 INCHES MAXIMUM |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
CPRQ | RESET METHOD | MANUAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39019/4 |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 CONTROL |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AGAV | III END ITEM IDENTIFICATION | DRAWER, POWER SUPPLY |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.797 INCHES MINIMUM AND 1.828 INCHES MAXIMUM |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE ONE |
SR-1 | MANUFACTURERS CODE | 81349 |