Item Name Circuit Breaker
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5925 Circuit Breakers
National Item Identification Number (NIIN) 01-048-0562 (010480562)
NCB Code USA (01)
Manufacturer Eaton Corporation, Heinemann Electric Co Inc
Part Number Manufacturer Item Name Cage Code RFQ
3XAM1516MG3-15-2 eaton corporation circuit breaker 74193 RFQ
3XAM1516MG3-15-208-2 eaton corporation circuit breaker 74193 RFQ
3XAM1516MG3-15-208-2 heinemann electric co inc circuit breaker l3330 RFQ
4SE00079-3 heinemann electric co inc circuit breaker l3330 RFQ

Technical Characteristics of NSN 5925010480562

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE
ADAQBODY LENGTH3.709 INCHES MINIMUM AND 3.729 INCHES MAXIMUM
ADATBODY WIDTH3.042 INCHES MINIMUM AND 3.062 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.053 INCHES MINIMUM AND 3.073 INCHES MAXIMUM
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHT0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.239 INCHES NOMINAL
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE15.0 AMPERES AC ALL LOCATIONS
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS208.0 AC ALL LOCATIONS
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1500.0 AC ALL LOCATIONS
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE,TWO,AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT5.500 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
CWJKCASE MATERIALPLASTIC
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD

Relevant Components for NSN - 5925-01-048-0562, 5925010480562
5975-01-629-6429 (5975016296429) 5998-01-305-2341 (5998013052341) 5930-01-584-0809 (5930015840809) 5962-01-210-3065 (5962012103065)
5905-00-175-4284 (5905001754284) 5950-01-458-0903 (5950014580903) 5920-01-490-0904 (5920014900904) 5998-01-475-9891 (5998014759891)
5995-01-575-7529 (5995015757529) 5962-01-310-7304 (5962013107304) 5935-01-240-1468 (5935012401468) 5995-01-374-0247 (5995013740247)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top