MRC | Criteria | Characteristic |
---|
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | SALT SPRAY PROOF |
MRC | Decoded Requirement | Clear Text Reply |
BBRJ | Special Handling Feature | MAGNETIC |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
THSD | Thread Series Designator | UNC |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
TEST | Test Data Document | 13499-260-4015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AKPX | Pole Quantity | 3 |
CSSX | Switch Current Rating And Type In Amps | 1.0 DC |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADAT | Body Width | 2.250 INCHES NOMINAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT EACH POLE |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AAJE | Thread Pitch Diameters | 0.1177 TO 0.1214 INCHES |
CSWP | Switch Voltage Rating And Type In Volts | 50.0 DC |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.611 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
CMLP | Thread Quantity Per Inch | 32 |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
PKWT | Unpackaged Unit Weight | 14.250 OUNCES |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 70.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQXF | Inclosure Protection Type For Which Designed | SHOCK RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | HUMIDITY RESISTANT AND |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |