MRC | Criteria | Characteristic |
---|
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBP | INPUT TERMINAL IDENTIFICATION | MIL-C-38999 |
AHBT | OUTPUT TERMINAL IDENTIFICATION | MIL-C-38999 |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AHCK | FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 3.0 AND 10.0 AND 20.0 AND 50.0 |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 500.0 VOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | TWENTY FILTERED FUNCTIONS; TWO GROUNDED CONTACTS; FOUR UNFILTERED CONTACTS; 15-19 TYPE INSERT ARRANGEMENT |
STYL | STYLE DESIGNATOR | FILTER CONNECTOR |
ABMK | OVERALL WIDTH | 1.209 INCHES MINIMUM AND 1.229 INCHES MAXIMUM |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 89954 |
AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
ABKW | OVERALL HEIGHT | 1.209 INCHES MINIMUM AND 1.229 INCHES MAXIMUM |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.6 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 89954 |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 26 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 260.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | BODY MATERIAL | METAL |
ABHP | OVERALL LENGTH | 1.719 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.123 INCHES MINIMUM AND 0.133 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.906 INCHES MINIMUM AND 0.969 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.906 INCHES MINIMUM AND 0.969 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 3.0 3RD RADIO INTERFERENCE 3RD FUNCTION |