Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 01-331-3906 (013313906)
NCB Code USA (01)
Manufacturer Pacific Aerospace And Electronics Inc, Litton Systems Inc, Corcom Inc, Spectrum Control Inc, Ems Development Corporation, The Captor Corporation
Part Number Manufacturer Item Name Cage Code RFQ
CNA 2001-05 pacific aerospace and electronics inc filter radio frequency interfere 66230 RFQ
841781-1 litton systems inc filter radio frequency interfere 13973 RFQ
1609191-7 corcom inc filter radio frequency interfere 05245 RFQ
5006-0035 spectrum control inc filter radio frequency interfere 13050 RFQ
RF12741 ems development corporation filter radio frequency interfere 13619 RFQ
WFV3570 corcom inc filter radio frequency interfere 05245 RFQ
A-5749 the captor corporation filter radio frequency interfere 23939 RFQ

Technical Characteristics of NSN 5915013313906

MRCCriteriaCharacteristic
ADAQBODY LENGTH4.720 INCHES MINIMUM AND 4.760 INCHES MAXIMUM
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS1.5 AND 3.0 AND 78.0 AND 100.0100.0 AND 100.0
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
CBBLFEATURES PROVIDEDFUNGUS RESISTANT AND SHOCK RESISTANT
CQJXNOMINAL THREAD SIZE0.164 INCHES
CQRGBODY MATERIALMETAL
CRSTBODY SURFACE TREATMENTTIN
CTJSUNPACKAGED UNIT WEIGHT3.000 POUNDS NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.090 INCHES MINIMUM AND 1.110 INCHES MAXIMUM
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
FEATSPECIAL FEATURESFOUR FILTERED FUNCTIONS
AFGAOPERATING TEMP RANGE-54.0 TO 65.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION125.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ20.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 4TH RADIO INTERFERENCE 4TH FUNCTION
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
ABHPOVERALL LENGTH6.080 INCHES MINIMUM AND 6.160 INCHES MAXIMUM
ADATBODY WIDTH2.570 INCHES MINIMUM AND 2.610 INCHES MAXIMUM
ADAUBODY HEIGHT2.570 INCHES MINIMUM AND 2.610 INCHES MAXIMUM
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
AFSVAVERAGE LIFE RATING IN HOURS1000.0
AGAVEND ITEM IDENTIFICATIONTACTICAL AIR OPERATIONS MODULE
AHASLOAD IMPEDANCE PER FUNCTION125.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.1 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY2 THREADED STUD GROUND 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION15.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION

Relevant Components for NSN - 5915-01-331-3906, 5915013313906
5975-01-629-6429 (5975016296429) 5998-01-305-2341 (5998013052341) 5930-01-584-0809 (5930015840809) 5962-01-210-3065 (5962012103065)
5905-00-175-4284 (5905001754284) 5950-01-458-0903 (5950014580903) 5920-01-490-0904 (5920014900904) 5998-01-475-9891 (5998014759891)
5995-01-575-7529 (5995015757529) 5962-01-310-7304 (5962013107304) 5935-01-240-1468 (5935012401468) 5995-01-374-0247 (5995013740247)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top