MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 10.434 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.286 INCHES MINIMUM AND 0.295 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 8.030 INCHES MAXIMUM |
ADAT | BODY WIDTH | 8.030 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 5.0 TO 33.0 |
AFGA | OPERATING TEMP RANGE | 0.0 TO 65.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | G225100 |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 62.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 62.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 62.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 62.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 62.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 62.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 15.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 96906 |
AHBP | INPUT TERMINAL IDENTIFICATION | MS3406D24-2S |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT 1ST FUNCTION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE 2ND FUNCTION |
CBBL | FEATURES PROVIDED | NUT AND WASHER |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE AND 135.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE AND 135.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE AND 135.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE AND 135.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE AND 135.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 6TH RADIO INTERFERENCE AND 135.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES |
CQRG | BODY MATERIAL | METAL |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.0 KILOVOLTS AT SEA LEVEL |
CTJS | UNPACKAGED UNIT WEIGHT | 16.000 POUNDS NOMINAL |
FEAT | SPECIAL FEATURES | SIX FILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |