INSTANT RFQ

Complete Listing of NSN (5915013178633) Parts 5915-01-317-8633

Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 01-317-8633 (013178633)
NCB Code USA (01)
Manufacturer Sora Power Inc, Filtronetics Inc, Raytheon Company
Part Number Manufacturer Item Name Cage Code RFQ
10B788 sora power inc filter radio frequency interfere 13058 RFQ
FN788 filtronetics inc filter radio frequency interfere 53733 RFQ
H960048-001B raytheon company filter radio frequency interfere 82577 RFQ

Technical Characteristics of NSN 5915013178633

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH4.093 INCHES NOMINAL
ABKWOVERALL HEIGHT2.900 INCHES NOMINAL
ADAQBODY LENGTH3.750 INCHES NOMINAL
ADATBODY WIDTH4.250 INCHES NOMINAL
ADAUBODY HEIGHT2.200 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.250 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 2000.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-55.0 TO 100.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION105.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION105.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION105.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION200.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION200.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE96906
AHBPINPUT TERMINAL IDENTIFICATIONMS27656T16B97P
AHCGMAXIMUM TEMP RISE40.0 DEG CELSIUS
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CBBLFEATURES PROVIDEDSHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY5 PIN OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION168.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION168.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION168.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
CQJXNOMINAL THREAD SIZE0.138 INCHES
CQRGBODY MATERIALALUMINUM
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE600.0 VOLTS AT SEA LEVEL
CRSTBODY SURFACE TREATMENTTIN
CTJSUNPACKAGED UNIT WEIGHT3.500 POUNDS NOMINAL
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES

Relevant Components for NSN - 5915-01-317-8633, 5915013178633
5975-01-629-6429 (5975016296429) 5998-01-305-2341 (5998013052341) 5930-01-584-0809 (5930015840809) 5962-01-210-3065 (5962012103065)
5905-00-175-4284 (5905001754284) 5950-01-458-0903 (5950014580903) 5920-01-490-0904 (5920014900904) 5998-01-475-9891 (5998014759891)
5995-01-575-7529 (5995015757529) 5962-01-310-7304 (5962013107304) 5935-01-240-1468 (5935012401468) 5995-01-374-0247 (5995013740247)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top