Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 00-677-0835 (006770835)
NCB Code USA (00)
Manufacturer Cornell Dubilier Electronics Corp, Northrop Grumman Systems Corporation, Ems Development Corporation, Westinghouse Electric Corp, Sprague Electric Co
Part Number Manufacturer Item Name Cage Code RFQ
NF10679-2 cornell dubilier electronics corp filter radio frequency interfere 93790 RFQ
328C046H01 northrop grumman systems corporation filter radio frequency interfere 97942 RFQ
98JX40A ems development corporation filter radio frequency interfere 13619 RFQ
328C046H01 westinghouse electric corp filter radio frequency interfere 79500 RFQ
98JX40A sprague electric co filter radio frequency interfere 56289 RFQ

Technical Characteristics of NSN 5915006770835

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH6.578 INCHES NOMINAL
ABKWOVERALL HEIGHT2.312 INCHES NOMINAL
ABMKOVERALL WIDTH3.983 INCHES MAXIMUM
ADAQBODY LENGTH6.078 INCHES NOMINAL
ADATBODY WIDTH2.859 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.196 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.703 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.859 INCHES NOMINAL
AFGAOPERATING TEMP RANGE0.0 TO 65.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 3RD RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 2ND RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS20.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB W/SCREW INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB W/SCREW OUTPUT 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION440.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQRGBODY MATERIALMETAL
CRSTBODY SURFACE TREATMENTTIN
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES

Relevant Components for NSN - 5915-00-677-0835, 5915006770835
5975-01-629-6429 (5975016296429) 5998-01-305-2341 (5998013052341) 5930-01-584-0809 (5930015840809) 5962-01-210-3065 (5962012103065)
5905-00-175-4284 (5905001754284) 5950-01-458-0903 (5950014580903) 5920-01-490-0904 (5920014900904) 5998-01-475-9891 (5998014759891)
5995-01-575-7529 (5995015757529) 5962-01-310-7304 (5962013107304) 5935-01-240-1468 (5935012401468) 5995-01-374-0247 (5995013740247)

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top