MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.200 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.270 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 60.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 118.8 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 43.65 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 87.75 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/12.0 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/15.0 1ST RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0/7.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0/9.0 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -9.0/9.0 4TH RESISTANCE-TEMPERATURE POINT |
AGAV | END ITEM IDENTIFICATION | RADAR SET |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CBME | CUBIC MEASURE | 0.002 CUBIC INCHES |
CQWD | ZERO POWER RESISTANCE | 75.000 OHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0/5.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-23648/19 GOVERNMENT SPECIFICATION |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 135.0 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
ADAR | BODY OUTSIDE DIAMETER | 0.090 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 0.25 WATTS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 102.75 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/15.0 6TH RESISTANCE-TEMPERATURE POINT |
AEBT | TERMINAL DIAMETER | 0.017 INCHES MINIMUM AND 0.023 INCHES MAXIMUM |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 57.75 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | ROD |