MRC | Criteria | Characteristic |
---|
AEJD | Temp Points For Resistance Readings At Zero Power | 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 35.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 48.5 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 12.4 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AKNA | Inclosure Type | ENCAPSULATED |
TTQY | Terminal Type And Quantity | 2 WIRE LEAD |
AEBT | Terminal Diameter | 0.008 INCHES NOMINAL |
AEHY | Ambient Temp At Full Rated Power | 25.0 DEG CELSIUS |
AEJD | Temp Points For Resistance Readings At Zero Power | 40.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 10.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 30.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 15.3 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 62.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 399.6 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 1.7 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | Resistance Tolerance At A Specified Temp In Percent | -0.2/+0.2 ALL RESISTANCE-TEMPERATURE POINTS |
MRC | Decoded Requirement | Clear Text Reply |
AARG | Reliability Indicator | NOT ESTABLISHED |
ABJT | Terminal Length | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
CQWD | Zero Power Resistance | 30.000 KILOHMS |
AEJA | Thermal Time Constant In Seconds | 10 |
AEJB | Power Dissipation Constant In Milliwatts Per Deg Celsius | 1 |
AEJD | Temp Points For Resistance Readings At Zero Power | 45.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 15.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 5.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | Temp Points For Resistance Readings At Zero Power | 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 19.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 787.9 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 23.8 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | Zero Power Resistance At Specified Temp | 80.7 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ADAR | Body Outside Diameter | 0.095 INCHES MAXIMUM |
CRQJ | Zero Power Resistance Tolerance In Percent At Reference Temp | -1 |
STYL | Style Designator | BEAD |