MRC | Criteria | Characteristic |
---|
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/125.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARA | TERMINAL QUANTITY | 16 |
AARB | TERMINAL TYPE | TAB,SOLDER LUG |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 0.125 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.735 INCHES MINIMUM AND 0.876 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.240 INCHES MINIMUM AND 0.305 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.200 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 1.500 TOTAL NETWORK |
AFWW | TERMINAL WIDTH | 0.015 INCHES MINIMUM AND 0.022 INCHES MAXIMUM |
CBME | CUBIC MEASURE | 0.053 CUBIC INCHES |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 1ST INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 3RD INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 4TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 5TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 6TH INTERMEDIATE RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 HIGHEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 1 LOWEST RESISTANCE VALUE |
CQRD | IDENTICAL VALUE RESISTOR QUANTITY | 3 2ND INTERMEDIATE RESISTANCE VALUE |
FEAT | SPECIAL FEATURES | BURN-IN REQUIRED |
PKWT | UNPACKAGED UNIT WEIGHT | 2.0 GRAMS |
STYL | STYLE DESIGNATOR | DUAL INLINE |
TEST | TEST DATA DOCUMENT | 73030-5E4795/136 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -200.0/200.0 |
AAPP | III ELECTRICAL RESISTANCE | 12.400 KILOHMS 3RD INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 15.000 KILOHMS 4TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 2.490 KILOHMS 1ST INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 22.600 KILOHMS 5TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 24.900 KILOHMS 6TH INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 38.300 KILOHMS HIGHEST RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 4.990 KILOHMS 2ND INTERMEDIATE RESISTANCE VALUE |
AAPP | III ELECTRICAL RESISTANCE | 402.000 OHMS LOWEST RESISTANCE VALUE |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -2.000/2.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 125.0 |