MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.300 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.391 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
ADAR | BODY OUTSIDE DIAMETER | 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 125.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 34.8 |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -65.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 11.2 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.1 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 6.0 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.1 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.4 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 9.7 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | ZERO POWER RESISTANCE | 5.000 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/10.0 |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
STYL | STYLE DESIGNATOR | ROD |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |