MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.410 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 0.140 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
AEHX | MAXIMUM POWER DISSIPATION RATING | 500.00 MILLIWATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 60.0 |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 123.2 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 166.1 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 184.4 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 259.6 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 308.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 357.1 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 409.2 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/12.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0/12.0 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0/17.0 6TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0/20.0 1ST RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
CQWD | ZERO POWER RESISTANCE | 2.700 KILOHMS |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/10.0 |
STYL | STYLE DESIGNATOR | ROD |
TEST | TEST DATA DOCUMENT | 81349-MILT23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |