Item Name | Resistor Variable Nonwire Wound |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5905 Resistors |
National Item Identification Number (NIIN) | 00-154-7022 (001547022) |
NCB Code | USA (00) |
Manufacturer | Andrew Scicomm Inc, Interlink Communications Inc, Ddc Pertec Peripherals Corp, Trw Limited, Mepcopal Co, Navy United States Department Of The, Bourns Instruments Inc, Vishay Thin Film Llc, Iv Electronic Klaus Vespermann Kg, Raytheon Company |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
719-011-102 | andrew scicomm inc | resistor variable nonwire wound | 17903 | RFQ |
40-001029-07 | interlink communications inc | resistor variable nonwire wound | 30890 | RFQ |
123-1020 | ddc pertec peripherals corp | resistor variable nonwire wound | 32097 | RFQ |
3329P102 | trw limited | resistor variable nonwire wound | 75042 | RFQ |
8014EMB102E1 | mepcopal co | resistor variable nonwire wound | 30983 | RFQ |
EC-0 125 490-2 | navy united states department of the | resistor variable nonwire wound | 28687 | RFQ |
3329P1-102 | bourns instruments inc | resistor variable nonwire wound | 80294 | RFQ |
65P102 | vishay thin film llc | resistor variable nonwire wound | 02111 | RFQ |
65P102 | iv electronic klaus vespermann kg | resistor variable nonwire wound | c7407 | RFQ |
585094-7 | raytheon company | resistor variable nonwire wound | 54x10 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | CYLINDRICAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.417 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.187 INCHES MINIMUM |
ABPM | BODY DIAMETER | 0.270 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.165 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.270 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 1.0 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CQTM | TERMINAL LOCATION | REAR END |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0 TO 20.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 30890-40-00102 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
Relevant Components for NSN - 5905-00-154-7022, 5905001547022 | ||||
5975-01-629-6429 (5975016296429) | 5998-01-305-2341 (5998013052341) | 5930-01-584-0809 (5930015840809) | 5962-01-210-3065 (5962012103065) | |
5905-00-175-4284 (5905001754284) | 5950-01-458-0903 (5950014580903) | 5920-01-490-0904 (5920014900904) | 5998-01-475-9891 (5998014759891) | |
5995-01-575-7529 (5995015757529) | 5962-01-310-7304 (5962013107304) | 5935-01-240-1468 (5935012401468) | 5995-01-374-0247 (5995013740247) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote